Skip to content Skip to navigation

Selected Publications

Journal Article
Earhart CM, Wilson RJ, White RL, Pourmand N, Wang SX.  2009.  Microfabricated magnetic sifter for high-throughput and high-gradient magnetic separation.. J Magn Magn Mater. 321(10):1436-1439.
Bechstein DJB, Ng E, Lee J-R, Cone SG, Gaster RS, Osterfeld SJ, Hall DA, Weaver JA, Wilson RJ, Wang SX.  2015.  Microfluidic multiplexed partitioning enables flexible and effective utilization of magnetic sensor arrays.. Lab Chip. 15(22):4273-6.
Zhao G, Hu J, Ouyang Y, He J, Wang SX, Yuan Z.  2015.  Mobile ions generated by external direct current electric field influence direct current measurement of giant magnetoresistance current sensors. Journal of Applied Physics. 117
Kim D, Lee J-R, Shen E, Wang SX.  2013.  Modeling and experiments of magneto-nanosensors for diagnostics of radiation exposure and cancer.. Biomed Microdevices. 15(4):665-71.
Ouyang Y., Hu J., He J., Zhao G., Xue F., Wang Z., Wang S.X, Yuan Z., Ding Z..  2014.  Modeling the Frequency Dependence of Packaged Linear Magnetoresisitive Sensors Based on MTJ. IEEE Transactions on Magnetics. 50:1-4.
Park S-min, Wong DJ, Ooi CChun, Kurtz DM, Vermesh O, Aalipour A, Suh S, Pian KL, Chabon JJ, Lee SHun et al..  2016.  Molecular profiling of single circulating tumor cells from lung cancer patients. Proceedings of the National Academy of Sciences. 113:E8379-E8386.
Sun S, Zeng H, Robinson DB, Raoux S, Rice PM, Wang SX, Li G.  2004.  Monodisperse MFe2O4 (M = Fe, Co, Mn) nanoparticles.. J Am Chem Soc. 126(1):273-9.
Park S-min, Won DD, Lee BJ, Escobedo D, Esteva A, Aalipour A, T. Ge J, Kim JHa, Suh S, Choi EH et al..  2020.  A mountable toilet system for personalized health monitoring via the analysis of excreta. Nature Biomedical Engineering .
Park S-min, Wong DJ, Ooi CChun, Nesvet JC, Nair VS, Wang SX, Gambhir SS.  2017.  Multigene profiling of single circulating tumor cells. Molecular & Cellular Oncology. 4:e1289295.
Guo Y, Deng Y, Wang SX.  2017.  Multilayer anisotropic magnetoresistive angle sensor. Sensors and Actuators A: Physical. 263:159-165.
Lee J-R, D Haddon J, Wand HE, Price JV, Diep VK, Hall DA, Petri M, Baechler EC, Balboni IM, Utz PJ et al..  2016.  Multiplex giant magnetoresistive biosensor microarrays identify interferon-associated autoantibodies in systemic lupus erythematosus.. Sci Rep. 6:27623.
Osterfeld SJ, Yu H, Gaster RS, Caramuta S, Xu L, Han S-J, Hall DA, Wilson RJ, Sun S, White RL et al..  2008.  Multiplex protein assays based on real-time magnetic nanotag sensing.. Proc Natl Acad Sci U S A. 105(52):20637-40.
Gaster RS, Hall DA, Wang SX.  2011.  nanoLAB: an ultraportable, handheld diagnostic laboratory for global health.. Lab Chip. 11(5):950-6.
Martin LW, Chu Y-H, Holcomb MB, Huijben M, Yu P, Han S-J, Lee D, Wang SX, Ramesh R.  2008.  Nanoscale control of exchange bias with BiFeO3 thin films.. Nano Lett. 8(7):2050-5.
Kim D, Marchetti F, Chen Z, Zaric S, Wilson RJ, Hall DA, Gaster RS, Lee J-R, Wang J, Osterfeld SJ et al..  2013.  Nanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation.. Sci Rep. 3:2234.
Donolato M, Gobbi M, Vavassori P, Leone M, Cantoni M, Metlushko V, Ilic B, Zhang M, Wang SX, Bertacco R.  2009.  Nanosized corners for trapping and detecting magnetic nanoparticles.. Nanotechnology. 20(38):385501.
Han J., Hu J., Yang Y., Wang Z., Wang S.X, He J..  2015.  A Nonintrusive Power Supply Design for Self-Powered Sensor Networks in the Smart Grid by Scavenging Energy From AC Power Line. IEEE Transactions on Industrial Electronics. 62:4398-4407.
Zhao G., Hu J., He J., Wang S.X.  2020.  A Novel Current Reconstruction Method Based on Elastic Net Regularization. IEEE Transactions on Instrumentation and Measurement. 69:7484-7493.
Han J, Hu J, Wang SX, He J.  2015.  A novel cylindrical torsional magnetoelectric composite based on d 15 shear-mode response. Journal of Physics D: Applied Physics. 48:045001.
Wang Z., Hu J., Han J., Zhao G., He J., Wang S.X.  2017.  A Novel High-Performance Energy Harvester Based on Nonlinear Resonance for Scavenging Power-Frequency Magnetic Energy. IEEE Transactions on Industrial Electronics. 64:6556-6564.
Wang Z., Hu J., Niu J., Han J., Wang S.X, He J..  2016.  A Novel Magnetic Energy Harvester Using Spinning Magnetoelectric Transducer. IEEE Transactions on Magnetics. 52:1-4.
Kemp JT, Davis RW, White RL, Wang SX, Webb CD.  2005.  A novel method for STR-based DNA profiling using microarrays.. J Forensic Sci. 50(5):1109-13.
Xue F, Hu J, Wang SX, He J.  2015.  Optimum direct current magnetic bias in ferromagnetic phase for improvement of magnetoelectric effect. Applied Physics Letters. 106
Wu Y., Zhao G., Hu J., Ouyang Y., Wang S.X, He J., Gao F., Wang S..  2019.  Overhead Transmission Line Parameter Reconstruction for UAV Inspection Based on Tunneling Magnetoresistive Sensors and Inverse Models. IEEE Transactions on Power Delivery. 34:819-827.
Zhao G, Hu J, Ma H, He J, Wang SX.  2020.  Parametric Reconstruction of Multiple Line Currents Based on Magnetic Sensor Array. IEEE TRANSACTIONS ON MAGNETICS. 56:4000908.

Pages